HP | PH | HZ | Voltz | Amps |
1 1/2 | 1 | 60 | 240 | 9.1 |
Performance
GPM | 0 | 20 | 25 | 30 | 35 | 40 | 50 | 60 |
PSI | – | 48 | 45 | 39 | 34 | – | – | – |
H2hOme® solutions are available for purchase through our network of select fire protection distributors. Please fill out the form to contact us for information on our readily available purchasing options.
A Note For Homeowners: Whether you’re building a new home or retrofitting your existing home with a fire sprinkler system, the entire system (including all of its’ components such as the H2hOme®) must be compliant with NFPA 13D residential fire sprinkler code. As such, the system and its components should always be installed and commissioned by a certified fire sprinkler contractor to ensure the system’s proper function and ultimately, the safety of your home. Please contact your local fire sprinkler contractor to see if the H2hOme® is right for your system, and to schedule your install.
H2Home® Model Specifications
MODEL | GPM | 0 | 20 | 25 | 30 | 35 | 40 | 50 | 60 |
H2H425-E01 | PSI | – | 26 | 24 | 20 | 18 | – | – | – |
H2H425-E03 | PSI | – | 48 | 46 | 39 | 34 | – | – | – |
H2H425-A04 | PSI | 61 | 57 | 54 | 52 | 50 | 46 | 39 | 37 |
H2H425-A06 | PSI | 72 | 67 | 65 | 63 | 60 | 58 | 51 | 45 |
NAFA13D Compliant.
NFPA 13D 6.2.1 (2):
Pump motors using ac power shall be rated for 240 V
and wired in accordance with the NEC (NFPA 70).
NFPA 13D 6.2.1 (4):
The pump shall be located not less than 1 ½ in. off the floor.
NFPA 13D 6.2.2 (1):
The test connection shall return water to the tank.
NFPA 13D 6.2.2 (3):
A method for determining the water level in the tank
shall be provided without having to open the tank.